When installing a slurry pump, the following checks should be carried out: (1) The dimensions, position, and elevation of the foundation must meet the design requirements. The foundation bolts must be properly and correctly fixed in the concrete foundation, and the machine must not be missing parts, damaged, or rusted; (2) According to the characteristics of the medium transported by the slurry pump, the materials of the main parts, shaft seals, and gaskets should be checked if necessary; (3) The leveling and alignment of the slurry pump must meet the requirements of the equipment technology. If there are no regulations, it should comply with the provisions of the current national standard "General Specifications for Construction and Acceptance of Mechanical Equipment Installation Engineering"; (4) The installation of all pipes and fittings connected to the slurry pump and the cleaning requirements of the lubricating oil pipelines must comply with the relevant national standards.